ATC-E EVAPORATIVE CONDENSERS

The ATC-E line of evaporative condensers represents Evapco’s commitment to product development. The line is comprised of 181 models ranging in size from 25 to 2,637 nominal ammonia tons (107 kW to 11,360 kW). The induced draft counterflow condensers are designed especially for easy maintenance and long, trouble-free operation

 

Features

Principle of operation: The refrigerant is circulated through the coil of the evaporative condenser. Heat from the refrigerant is dissipated through the coil tubes to the water cascading downward over the tubes. Simultaneously, air is drawn in through the air inlet louvers at the base of the condenser and travels upward over the coil opposite the water flow. A small portion of the water is evaporated which removes the heat. The warm moist air is drawn to the top of the evaporative condenser by the fan and is discharged to the atmosphere. The remaining water falls to the sump at the bottom of the condenser where it is recirculated by the pump up through the water distribution system and back down over the coils.

 

Superior Air Inlet Louver and Screen Design: The air inlet louver screens on the ATC are constructed of corrosion-free PVC. They are a two pass design that minimizes splashout and reduces the potential for algae formation inside the condenser.

 

In single pass louver systems used by other manufacturers, circulating water droplets tend to splashout, especially when the fans are shut off. With the two pass louver system, the water droplets are captured on the inward sloping pass, minimizing splashout problems.

 

Thermal-Pak II Coil: EVAPCO’s Thermal-Pak II ® coils feature a patented design which assures maximum cooling capacity. The airflow through the coil is counterflow to the fluid flow, providing the most efficient heat transfer process. A special coil design is utilized to reduce the air pressure drop through the unit while maximizing tube surface area and increasing its heat transfer capabilities. The uniquely shaped tubes of the coil are staggered in the direction of airflow to obtain a high film coefficient.

 

The coils are manufactured from high quality steel tubing following the most stringent quality control procedures. Each circuit is inspected to assure the material quality and then tested before being assembled into a coil. Finally, the assembled coil is pneumatically tested at 400 psig (2758 kPa) under water to ensure it is leak free. To protect the coil against corrosion, it is placed in a heavy steel frame and then the entire assembly is dipped in molten zinc (hot-dip galvanized) at a temperature of approximately 800°F (427º).

 

 

Pressurized Water Distribution System: EVAPCO’s Zero Maintenance ZMII® Spray Nozzle remains clogfree while providing even and constant water distribution for reliable, scale-free evaporative cooling under all operating conditions. The heavy duty nylon ZMII® Spray nozzles have a 1-1/4″ diameter opening and a 1-1/4″ splash plate clearance. Furthermore, the fixed position ZMII® nozzles are mounted in corrosion-free PVC water distribution pipes that have threaded end caps. Together, these elements combine to provide unequaled coil coverage and scale prevention, and make the industry’s best performing non-corrosive, maintenance-free water distribution system.

 

The water distribution is designed to provide a minimum 6 GPM over each square foot (4 liters per second over each square meter) of unit plan area to ensure proper flooding of the coil.

Category

Evaporating Condensers